We accept

Visa and Mastercard

 

Type M-T-TPE ( Borealis NO. 5595) Heating Cable
Low Temperature - Constant Wattage

Specifications:

  • Supply Power 120, 240 Volts
  • Wattage 3, 5, 9 - Watts per foot
  • Module Length 24 inches (*1)
  • Maximum Circuit Length 660 Feet (*1)
  • Continuous Operating Temperature 220º F / 105º C
  • Maximum Exposure Temperature 260º F / 127º C (De-energized)
  • Dielectric Strength Spark Test 4000 VAC
  • UL & CSA Approved

Construction:    

Buss Wire - 2/C  #16  AWG (19/29) bare stranded copper

Buss Insulation - TPE extruded jacket

Binder - Nominal 30 mil. of  (TPE -Borealis NO. 5595)  extruded in a figure-8 design

Heating Element - Nickel-Chromium resistive wire #38, #39 or #40 AWG

Jacket - Nominal 30 / 40 mil. of (TPE -Borealis NO. 5595) extruded overall


 

Also Available:

Overbraids of tinned or nickel plated copper and stainless steel

Overjacket of PVC, - *Teflon FEP, PFA or Tefzel*

Monitor wire

Custom constructions


 

Features:

Low Cost - This cable is manufactured utilizing PVC or TPE insulation when applicable.

Constant Wattage - Uniform heat, wattage remains the same, regardless of circuit length.

Zone Modules - Hand soldered and inspected to maintain 100% contact with buss wires.

Cut to Length on Site - Parallel resistance type heater eliminates the need for inventories of different size heaters.

 

Application:

This cable is designed for low temperature applications including freezers and animal pen enclosures. 

 

Caution:  

Type M-T-TPE cable can be overlapped provided that the process temperature

is less than 140°F.

 

*1- Depending on the Voltage and Wattage Specified

 

 
Footer