Specifications:
· Supply Power
120, 240, 480 - Volts
· Wattage
3, 5, 9, 17 - Watts per Foot
· Module Length
24 - Inches (*1)
· Maximum Circuit Length
720 feet (*1)
· Continuous Operating
Temperature
450º F / 232º C
· Maximum Exposure Temperature
500º F / 260º C (De-energized)
· Dielectric Strength
Spark Test 4000 VAC
· UL Approved
Construction:
Buss
Wire - 2/C #12 AWG tin coated stranded copper
2/C
#12 AWG nickel plated stranded copper (optional)
Buss
Insulation - PFA Teflon extruded jacket
Binder
- PFA Teflon extruded in a figure-8 design
Heating
Element - Nickel-Chromium resistive wire
Jacket
- PFA Teflon extruded overall
Also Available:
Overbraids
of tinned or nickel plated copper and stainless steel
Overjackets
of PVC, TPE, Teflon* FEP, PFA or Tefzel*
Monitor
wire
Custom
constructions
Features:
PFA Teflon - Entire construction employs Dupont PFA Teflon which is unaffected by chemicals
and solvents that may cause rapid deterioration of other plastics and
all but the most expensive metal alloys. High resistance to moisture,
flame, and radiation is also realized.
Optional Nickel Plated Bus Wires - For maximum thermal and corrosion protection.
Constant Wattage - Uniform heat; wattage remains the same regardless of circuit length.
Zone Modules - Hand
soldered and inspected to maintain 100% contact with bus wires.
Cut to Length on Site - Parallel resistance type heater eliminates the need for inventoriesof
different size heaters.
Caution:
Type
M-T-PFA cable can be overlapped provided that the process temperature
is
less than 310°F.
*1-
Depending on the Voltage and Wattage Specified
|