Specifications:
· Supply Power
120, 240, 480 - Volts
· Wattage
3, 5, 9, 17 - Watts per Foot
· Module Length
24 - Inches ( *1)
· Maximum Circuit Length
720 feet ( *1)
· Continuous Operating
Temperature
400º F / 204º C
· Maximum Exposure Temperature
450º F / 232º C (De-energized)
· Dielectric Strength
Spark Test 4000 VAC
· UL Approved
Construction:
Bus
Wire - 2/C #12 AWG tin coated stranded copper
2/C
#12 AWG nickel plated stranded copper (optional)
Bus
Insulation - FEP Teflon extruded jacket
Binder
- FEP Teflon extruded in a figure-8 design
Heating
Element - Nickel-Chromium resistive wire
Jacket
- FEP Teflon extruded overall
Also Available:
Overbraids
of tinned or nickel plated copper and stainless steel
Overjackets
of PVC, TPE, Teflon* FEP, PFA or Tefzel*
Monitor
wire
Custom
constructions
Features:
FEP Teflon - Entire construction employs Dupont FEP Teflon which is unaffected by chemicals
and solvents that may cause rapid deterioration of other plastics and
all but the most expensive metal alloys. High resistance to moisture,
flame, and radiation is also realized.
Optional Nickel Plated Bus Wires - For maximum thermal and corrosion protection.
Constant Wattage - Uniform heat; wattage remains the same regardless of circuit length.
Zone Modules - Hand soldered and inspected to maintain 100% contact with bus wires.
Cut to Length on Site - Parallel resistance type heater eliminates the need for inventories
of different size heaters.
Caution:
Type
M-T-FEP cable can be overlapped provided that the process temperature
is
less than 250°F.
*1 - Depending on the Voltage and Wattage Specified
|